Medical first-aid ventilator equipment. It is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc., it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.
Specifications:
1. Gas drive and electrical control, time-pressure switching and pressure limit control.
2. A high-brightness digital display is used to present the control frequency, tidal volume, throughput, overall respiratory rate, spontaneous breathing frequency, etc.
3. A highly sensitive and responsive pressure sensor and a flow sensor are used to measure, control and display the airway pressure and gas flow rate and the ventilator is equipped with automatic throughput compensation.
4. In case of an abnormality to the ventilator or misoperation, the ventilator can raise a visual-audible alarm to automatically protect itself.
Innovative ventilator for surgical room. Medical first-aid ventilator equipment. It is an electrically controlled pneumatic ventilator
integrating such functions as time, volume cycling, pressure limit, etc. , it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.
Specifications:
1. Gas drive and electrical control, time-pressure switching and pressure limit control.
2. A high-brightness digital display is used to present the control frequency, tidal volume, throughput, overall respiratory rate, spontaneous breathing frequency, etc.
3. A highly sensitive and responsive pressure sensor and a flow sensor are used to measure, control and display the airway pressure and gas flow rate and the ventilator is equipped with automatic throughput compensation.
4. In case of an abnormality to the ventilator or misoperation, the ventilator can raise a visual-audible alarm to automatically protect itself.
Air Compressor:
Power: AC220V + 22 v, 50 Hz + 1 Hz and 300 va has a good reserve of single-phase ac power supply;
FUSE: Φ 5 x 20 / F8A;
Output gas pressure: 0.3 ~ 0.4 MPa.
Portable medical ventilator. It is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. , it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.
Component Details
Display: 10.4''LCD ;
Gas drive and electrical control, time-pressure switching and pressure limit control.
A high-brightness digital display is used to present the control frequency, tidal volume, throughput, overall respiratory rate, spontaneous breathing frequency, etc.
A highly sensitive and responsive pressure sensor and a flow sensor are used to measure, control and display the airway pressure and gas flow rate and the ventilator is equipped with automatic throughput compensation.
In case of an abnormality to the ventilator or misoperation, the ventilator can raise a visual-audible alarm to automatically protect itself.
Ventilator Construction:
--Environmentally safe material construction, hard to be broken.
-- Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions.
High quality medical ventilator machine. It is gas driven by medical compressed oxygen and compressed air. In the aspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure. Other specifications:
- Operating mode and respiratory rate;
- Ventilator control frequency set by medical staff;
- Tidal volume of each breath in the patient;
- Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
Ventilator Construction:
--Environmentally safe material construction, hard to be broken.
-- Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions.
Best quality infant ventilator. Function features:
1.Microprocessor based servo controlled temperature system
2. Temperature displayed by LED
3. Alarm functions: power failure; over temperature; temperature deviation; temperature sensor failure; fan failure;
4.Temperature setting
5.A keypad lock helps preventing inadvertent changes the setting
6.Temperature deviation and over temperature could be amended in front panel directly
7.Heater is electrically cut-out if air temperature inside incubator exceed 8.The infant bed inclination angle is adjustable
9.Humidity is adjustable in two grades
10.Trough for pulling and pushing ,which is convenient to add the water and wash
11.Fan with low noise and long life-span
12.Six operating windows, two side operating windows can be swiveled
13.Integral timer to record therapy time
14.A second thermal cut-off function for more safety.